102PLCGSM 102PLCGSM Modbus RTU GSM modem
COMMUNICATION & MONITORING

Modbus RTU GSM modem — 102PLCGSM

PLC with GSM, 12 DI / 4 DO.

12 inputs4 relays24 V DC
Specifications
Power supply
24 V DC, 5 W
Inputs
12 pcs, optocoupler, 24 V DC, 5 mA
Outputs
4 relays, changeover contact NO/NC, 250 V AC, 10 A, 50 Hz, cos φ > 0.95
Output
T1 PNP transistor, BDW94C
Galvanic isolation of power supply and interface
1500 V, 50 Hz
101PLC 101PLC programmable controller
PROGRAMMABLE CONTROLLER

101PLC programmable controller

PLC for control panels.

16 inputs6 relays24 V DC
Specifications
Power supply
24 V DC, 8 W
Inputs
16 pcs, optocoupler, 24 V DC, 8 mA
Outputs
6 relays, changeover contact NO/NC, 250 V AC, 10 A, 50 Hz, cos φ > 0.95
Output
T1, T2 PNP transistor (Darlington), BDW94C
Galvanic isolation of power supply and interfaces
1500 V, 50 Hz
АГП103 АГП103 boiler controller (v1)
BOILER CONTROL

АГП103 boiler controller (v1)

Burner / boiler controller, version v1.

12 inputs10 relaysRS-485
Specifications
Power supply
24 V DC, 5 W
Inputs
12 pcs, optocoupler, 24 V DC, 5 mA
Outputs
10 relays, changeover contact NO/NC, 250 V AC, 10 A, 50 Hz, cos φ > 0.95
Galvanic isolation of power supply and interface
1500 V, 50 Hz
Interface
RS-485
АГП103 АГП103 boiler controller, networked (v2)
BOILER CONTROL

АГП103 boiler controller, networked (v2)

Controller with network operation support, v2.

12 inputs10 relaysRS-485
Specifications
Power supply
24 V DC, 5 W
Inputs
12 pcs, optocoupler, 24 V DC, 5 mA
Outputs
10 relays, changeover contact NO/NC, 250 V AC, 10 A, 50 Hz, cos φ > 0.95
Galvanic isolation of power supply and interface
1500 V, 50 Hz
Interface
RS-485
АГП103 АГП103 boiler controller (v3)
BOILER CONTROL

АГП103 boiler controller (v3)

Modified version v3.

12 inputs10 relaysRS-485
Specifications
Power supply
24 V DC, 5 W
Inputs
12 pcs, optocoupler, 24 V DC, 5 mA
Outputs
10 relays, changeover contact NO/NC, 250 V AC, 10 A, 50 Hz, cos φ > 0.95
Galvanic isolation of power supply and interface
1500 V, 50 Hz
Interface
RS-485
2018DO
OUTPUT MODULE

2018DO discrete outputs

8 relay output channels, 220 V AC, up to 10 A.

8 relaysRS-48524 V DC
Specifications
Power supply
24 V DC, 5 W
Outputs
8 relays, changeover contact NO/NC, 250 V AC, 10 A, 50 Hz, cos φ > 0.95
Galvanic isolation of power supply and interface
1500 V, 50 Hz
Interface
RS-485
Protocol
Modbus RTU, 2.4-115.2 kbaud, address 1-247
Details
20240DI 20240DI inputs
INPUT MODULE

20240DI inputs

40 discrete inputs, 24 V.

40 inputsRS-48524 V DC
Specifications
Power supply
24 V DC, 6 W
Inputs
40 pcs, optocoupler, 24 V DC, 5 mA
Galvanic isolation of power supply and interface
1500 V, 50 Hz
Interface
RS-485
Protocol
Modbus RTU, 2.4-115.2 kbaud, address 1-247
2058AI
INPUT MODULE

2058AI analog inputs

8 analog inputs (mA, Pt100 resistance thermometers).

8 inputsRS-48524 V DC
Specifications
Power supply
24 V DC, 5 W
Inputs
8 pcs, Pt100, 0-20 mA, 4-20 mA
Galvanic isolation of power supply and interface
1500 V, 50 Hz
Interface
RS-485
Protocol
Modbus RTU, 2.4-115.2 kbaud, address 1-247
Details
20312 6_ProtectSensor — 20312…
INPUT MODULE

ProtectSensor — 20312

12 DI for intrinsically safe sensors, 24 V.

12 inputsRS-48524 V DC
Specifications
Power supply
24 V DC, 5 W
Inputs
12 pcs, optocoupler, 24 V DC, 10 mA
Galvanic isolation of power supply and interface
1500 V, 50 Hz
Interface
RS-485
Protocol
Modbus RTU, 2.4-115.2 kbaud, address 1-247
20416 6_ProtectSensor — 20416…
INPUT MODULE

ProtectSensor — 20416

16 DI for intrinsically safe sensors, 24 V.

16 inputsRS-48524 V DC
Specifications
Power supply
24 V DC, 5 W
Inputs
16 pcs, optocoupler, 24 V DC, 10 mA
Galvanic isolation of power supply and interface
1500 V, 50 Hz
Interface
RS-485
Protocol
Modbus RTU, 2.4-115.2 kbaud, address 1-247
302Ind4DigModBus 302Ind4DigModBus indicator
INDICATOR

302Ind4DigModBus indicator

Four-digit indicator with Modbus RTU interface.

4 inputsRS-48524 V DC
Specifications
Power supply
24 V DC, 5 W
Inputs
4 pcs, Pt100, 0-20 mA, 4-20 mA
Galvanic isolation of power supply and interface
1500 V, 50 Hz
Interface
RS-485
Protocol
Modbus RTU, 2.4-115.2 kbaud, address 1-247
05 / TECHNICAL SUPPORT

Have a task?
Let’s start with a solution.

To help us select equipment, please prepare the boiler type, a list of sensors and actuators, and your control requirements.

What does technical support include?

Advice on selecting and configuring equipment manufactured by PLCinger.

How do I contact the service department?

Email service@plcinger.ru or call +7 930 333-49-30.

Where can I find wiring diagrams and manuals?

Links to operating manuals, quick guides and technical passports are in the equipment cards. The complete documentation set is in the catalog.

Who does PLCinger work with?

Manufacturers of boiler and heating equipment, as well as design, procurement and installation companies.